Author

BoguslawTomanek

Unknown affiliation - Cited by 5,472

Biography

Methods allowing quantification of cancer metabolites in vivo based on Magnetic Resonance (MR) spectral profiles have been developed and are currently being considered for clinical routines. MR Spectroscopy (MRS) is noninvasive, nondestructive and enables serial measurements of tissue. MRS spectra can be obtained from the entire sample or from specific regions of interest (localized MRS). MRS is the in vivo application of (NMR) spectroscopy, and is implemented on (MRI) clinical or experimental scanners
Title
Cited by
Year
Design and Regulation of NaHoF4 and NaDyF4 Nanoparticles for High-Field Magnetic Resonance Imaging
X Zhang, B Blasiak, AJ Marenco, S Trudel, B Tomanek, FCJM van VeggelChemistry of Materials 28 (9), 3060-30, 2016201
72
2016
Hyperpolarized and inert gas MRI: the future
MJ Couch, B Blasiak, B Tomanek, AV Ouriadov, MS Fox, KM Dowhos, ...Molecular Imaging and Biology 17, 149-162, 2015201
60
2015
Lactate storm marks cerebral metabolism following brain trauma
S Lama, RN Auer, R Tyson, CN Gallagher, B Tomanek, GR SutherlandJournal of Biological Chemistry 289 (29), 20200-20208, 2014201
59
2014
Synthesis, characterization, and evaluation of PEGylated first-row transition metal ferrite nanoparticles as T 2 contrast agents for high-field MRI
A Banerjee, B Blasiak, E Pasquier, B Tomanek, S TrudelRSC advances 7 (61), 38125-38134, 2017201
42
2017
High‐resolution MRI encoding using radiofrequency phase gradients
JC Sharp, SB King, Q Deng, V Volotovskyy, B TomanekNMR in Biomedicine 26 (11), 1602-1607, 2013201
32
2013
Evaluation of blood–brain barrier-stealth nanocomposites for in situ glioblastoma theranostics applications
CH Su, CY Tsai, B Tomanek, WY Chen, FY ChengNanoscale 8 (15), 7866-7870, 2016201
28
2016
Validation of Inner, Second, and Outer Sphere Contributions to T1 and T2 Relaxation in Gd3+-Based Nanoparticles Using Eu3+ Lifetime Decay as a Probe
A Dash, B Blasiak, B Tomanek, FCJM van VeggelThe Journal of Physical Chemistry C 122 (21), 11557-11569, 2018201
25
2018
Optimal dye-quencher pairs for the design of an “activatable” nanoprobe for optical imaging
B Simard, B Tomanek, FCJM van Veggel, A AbulrobPhotochemical & Photobiological Sciences 12 (10), 1824-1829, 2013201
23
2013
Comparison of T2 and T2*-weighted MR molecular imaging of a mouse model of glioma
B Blasiak, S Barnes, T Foniok, D Rushforth, J Matyas, D Ponjevic, ...BMC medical imaging 13 (1), 1-8, 2013201
22
2013
K-space trajectory mapping and its application for ultrashort Echo time imaging
P Latta, Z Starčuk Jr, MLH Gruwel, MH Weber, B TomanekMagnetic Resonance Imaging 36, 68-76, 2017201
21
2017
Molecular susceptibility weighted imaging of the glioma rim in a mouse model
B Blasiak, J Landry, R Tyson, J Sharp, U Iqbal, A Abulrob, D Rushforth, ...Journal of neuroscience methods 226, 132-138, 2014201
16
2014
HyperCEST detection of cucurbit [6] uril in whole blood using an ultrashort saturation Pre‐pulse train
FT Hane, PS Smylie, T Li, J Ruberto, K Dowhos, I Ball, B Tomanek, ...Contrast Media & Molecular Imaging 11 (4), 285-290, 2016201
15
2016
Bifunctional pyrrolidin-2-one terminated manganese oxide nanoparticles for combined magnetic resonance and fluorescence imaging
A Banerjee, GE Bertolesi, CC Ling, B Blasiak, A Purchase, O Calderon, ...ACS applied materials & interfaces 11 (14), 069-078, 2019201
13
2019
LyP-1 conjugated nanoparticles for magnetic resonance imaging of triple negative breast cancer
A Abulrob, S Corluka, B Blasiak, B Gino Fallone, D Ponjevic, J Matyas, ...Molecular Imaging and Biology 20, 428-435, 2018201
12
2018
Maltol‐Functionalized Fe3O4 Nanoparticles as T2 Magnetic Resonance Imaging Contrast Agents
TW Clements, C Sarsons, CM Platnich, A Banerjee, B Blasiak, B Tomanek, ...ChemistrySelect 1 (8), 1602-1606, 2016201
12
2016
A short and light, sparse dipolar Halbach magnet for MRI
AR Purchase, L Vidarsson, K Wachowicz, P Liszkowski, H Sun, GE Sarty, ...IEEE Access 9, 95294-95303, 2021202
11
2021
White and gray matter contrast enhancement in MR images of the mouse brain in vivo using IR UTE with a cryo-coil at 9.4 T
W Piędzia, K Jasiński, K Kalita, B Tomanek, WP WęglarzJournal of neuroscience methods 232, 30-35, 2014201
10
2014
Design of a high power PIN‐diode controlled switchable RF transmit array for TRASE RF imaging
E Der, V Volotovskyy, H Sun, B Tomanek, JC SharpConcepts in Magnetic Resonance Part B: Magnetic Resonance Engineering 48 (1 …, 2018201
10
2018
Challenges in developing a magnetic resonance–compatible haptic hand-controller for neurosurgical training
Y Maddahi, K Zareinia, B Tomanek, GR SutherlandProceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2018201
9
2018
MRI-based assessment of liver perfusion and hepatocyte injury in the murine model of acute hepatitis
K Byk, K Jasinski, Z Bartel, A Jasztal, B Sitek, B Tomanek, S Chlopicki, ...Magnetic Resonance Materials in Physics, Biology and Medicine 29, 89-98, 2016201
7
2016